Microbiology Lab Equipment

HOME > Microbiology Lab Equipment
> DonWhitley Scientific > Hypoxia/Cell Culture Workstations

  • Whitley H35 Workstation

    [Features]
    • O2 adjustment: 0.1% to 20%. (minimum adjustment 0.1%)•CO2 adjustment: 0.1% to 15%. (minimum adjustment unit 0.1%)•Fine adjustment of O2 and CO2 concentration for more reliable results.

    • Accurate temperature setting, maintenance and adjustment inside the chamber.

    • Automatic dehumidification function and adjustable relative humidity up to 80% or more. (optional: Automatic Humidifier)

    • Gas mixing is performed by a built-in regulating system inside the instrument, which can be easily and quickly set to the user’s desired conditions.

    • Simple and easy gas sensor calibration.

  • Whitley H35  HEPA Workstation

    [Features]
    • O2 adjustment: 0.1% to 20%. (minimum adjustment 0.1%)•CO2 adjustment: 0.1% to 15%. (minimum adjustment unit 0.1%)•Fine adjustment of O2 and CO2 concentration for more reliable results.

    • Accurate temperature setting, maintenance and adjustment inside the chamber.

    • Automatic dehumidification function and adjustable relative humidity up to 80% or more. (optional: Automatic Humidifier)

    • Gas mixing is performed by a built-in regulating system inside the instrument, which can be easily and quickly set to the user’s desired conditions.

    • Simple and easy gas sensor calibration.

  • Whitley H45 Workstation

    [Features]
    • O2 adjustment: 0.1% to 20%. (minimum adjustment 0.1%)•CO2 adjustment: 0.1% to 15%. (minimum adjustment unit 0.1%)•Fine adjustment of O2 and CO2 concentration for more reliable results.

    • Accurate temperature setting, maintenance and adjustment inside the chamber.

    • Automatic dehumidification function and adjustable relative humidity up to 80% or more. (optional: Automatic Humidifier)

    • Gas mixing is performed by a built-in regulating system inside the instrument, which can be easily and quickly set to the user’s desired conditions.

    • Simple and easy gas sensor calibration.

  • Whitley H85 Workstation

    [Features]
    • O2 adjustment: 0.1% to 20%. (minimum adjustment 0.1%)•CO2 adjustment: 0.1% to 15%. (minimum adjustment unit 0.1%)•Fine adjustment of O2 and CO2 concentration for more reliable results.

    • Accurate temperature setting, maintenance and adjustment inside the chamber.

    • Automatic dehumidification function and adjustable relative humidity up to 80% or more. (optional: Automatic Humidifier)

    • Gas mixing is performed by a built-in regulating system inside the instrument, which can be easily and quickly set to the user’s desired conditions.

    • Simple and easy gas sensor calibration.

  • Whitley H135 HEPA Workstation

    [Features]
    • O2 adjustment: 0.1% to 20%. (minimum adjustment 0.1%)•CO2 adjustment: 0.1% to 15%. (minimum adjustment unit 0.1%)•Fine adjustment of O2 and CO2 concentration for more reliable results.

    • Accurate temperature setting, maintenance and adjustment inside the chamber.

    • Automatic dehumidification function and adjustable relative humidity up to 80% or more. (optional: Automatic Humidifier)

    • Gas mixing is performed by a built-in regulating system inside the instrument, which can be easily and quickly set to the user’s desired conditions.

    • Simple and easy gas sensor calibration.